Herco ACR SYSTEM 23-1000 other climate control equipment





If you decide to buy equipment at a low price, make sure that you communicate with the real seller. Find out as much information about the owner of the equipment as possible. One way of cheating is to represent yourself as a real company. In case of suspicion, inform us about this for additional control, through the feedback form.
Before you decide to make a purchase, carefully review several sales offers to understand the average cost of your chosen equipment. If the price of the offer you like is much lower than similar offers, think about it. A significant price difference may indicate hidden defects or an attempt by the seller to commit fraudulent acts.
Do not buy products which price is too different from the average price for similar equipment.
Do not give consent to dubious pledges and prepaid goods. In case of doubt, do not be afraid to clarify details, ask for additional photographs and documents for equipment, check the authenticity of documents, ask questions.
The most common type of fraud. Unfair sellers may request a certain amount of advance payment to “book” your right to purchase equipment. Thus, fraudsters can collect a large amount and disappear, no longer get in touch.
- Transfer of prepayment to the card
- Do not make an advance payment without paperwork confirming the process of transferring money, if during the communication the seller is in doubt.
- Transfer to the “Trustee” account
- Such a request should be alarming, most likely you are communicating with a fraudster.
- Transfer to a company account with a similar name
- Be careful, fraudsters may disguise themselves as well-known companies, making minor changes to the name. Do not transfer funds if the company name is in doubt.
- Substitution of own details in the invoice of a real company
- Before making a transfer, make sure that the specified details are correct, and whether they relate to the specified company.
Seller's contacts


Marke: Herco
2008 Herco ACR SYSTEM 23-1000
ACTIVATED CARBON RECOVERY SYSTEM
Gas recovery system
The installation is 10 years old
has a max. adsorption capacity for 75 fridges per hour
with a suction capacity of 850 m³/h
It is a system with activated carbon adsorption
with desorption over a cryo-unit
Designated Application
Scope of Application
The delivered recovery plant is designed and manufactured for reclaiming
propellants refrigerator recycling. The propellants
vaporized during the
shredding process
are sucked off from the shredder and adsorbents in the
recovery plant
Other applications are not provided. If the plant is used for other applications
only the user carries the whole risk for damages
General data
Application : Propellant recovery
Plant designation : Activated carbon recovery system
Plant type : ACR-SYSTEM 23-1000
Technical data
Capacity : max. process gas flow 1000 m3/h
(oil- and dust-free)
Propellants : R11
R12
Cyclopentane max 10% R12
Propellants mass flow : 22,5 kg/h
Water mass flow : 60,0 kg/h
Process gas temperature : 52 °C
Outlet concentration R11 : <20 mg/Nm³
Outlet concentration R12 : <20 mg/Nm³
Outlet concentration Cyclopentane : <50 mgC/Nm³
Dimensions : see drawing 3673-04/A
Electrical power supply : 3/PE/50Hz/400V/350A
Control voltage : 230V AC / 24V DC
Location : 5°C…30°C
Pneumatic air supply : 6 bar (oil and water free) / 2 m³/h
Component overview
adsorber unit 3
process gas fan 1
process gas cooler 1
water drop separator 2
process gas heater 1
desorption gas fan 1
desorption gas cooler 1
desorption gas heater 1
refrigerant compressor 1
refrigerant evaporator 1
refrigerant condenser 1
brine buffer 1
brine pump 4
condensed water pump 1
cooling water cooler 1
cooling water pump 3
gas analyser cabinet 1
control cabinet 1
process gas compressor 1
low temperature condenser 1
rekuperator 1
molecular sieve 2